G5V-1
Low Signal Relay
Ultra-miniature, Highly Sensitive
SPDT Relay for Signal Circuits
• Ultra-miniature at 12.5 × 7.5 × 10 mm (L × W × H).
• Wide switching power of 1 mA to 1 A.
• High sensitivity: 150 mW nominal coil power consumption.
• Fully-sealed construction offering environment resistance.
• Conforms to FCC Part 68 requirements for coil to contacts.
(1,500 V, 10 × 160 μs)
• Models for ambient temperatures up to 90°C added to series.
RoHS Compliant
■Model Number Legend
G 5 V-@- @
— —
1
■Application Examples
1. Number of Poles/Contact Form
1: 1-pole/SPDT (1c)
2
Enclosure
Contact form
rating
Terminal
Shape
Model
G5V-1
Standard
Fully
sealed
SPDT
(1c)
G
5
V
1
■Standard Model Specifications
■Ordering Information
Classification
Telecommunication equipment
Audio-visual products
Security equipment
Building automation equipment
-
2. Classification
None: Standard (Ambient operating temperature 70°C max.)
T90: Ambient operating temperature 90°C max.
•
•
•
•
PCB
terminals
G5V-1-T90
G5V-1-T90
Rated coil
voltage
3 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
Minimum
packing unit
Contact type: Single crossbar (Au-alloy + Ag)
Enclosure rating: Plastic sealed
Terminal shape: PCB terminals
25 pcs/tube
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-1 DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
■Ratings
●Coil
G5V-1 (Standard)
●Contacts
Rated voltage
Rated
current
(mA)
Coil
resistance
(Ω)
3 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
50
30
25
16.7
12.5
6.25
60
167
240
540
960
3,840
Rated voltage
Rated
current
(mA)
Coil
resistance
(Ω)
5 VDC
12 VDC
24 VDC
30
12.5
6.25
167
960
3,840
Must operate Must release
Max. voltage
Power
voltage
voltage
(V)
consumption
(V)
(V)
(mW)
% of rated voltage
80% max.
10% min.
200% at
23°C
Approx. 150
G5V-1-T90
Must operate Must release
Max. voltage
Power
voltage
voltage
(V)
consumption
(V)
(V)
(mW)
% of rated voltage
70% max.
10% min.
200% at
23°C
Load
Resistive load
Item
Contact type
Single crossbar
Contact
Au-alloy + Ag
material
0.5 A at 125 VAC;
Rated load
1 A at 24 VDC
Rated carry
2A
current
Max. switching
125 VAC, 60 VDC
voltage
Max. switching
1A
current
Approx. 150
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance
of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. G5V-1-2 types with a must operate voltage of 70% max. are available as special series products.
1
G5V-1
Low Signal Relay
■Characteristics
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Dielectric
strength
Vibration
resistance
Shock
resistance
Durability
Between coil and contacts
Between contacts of the same polarity
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
Failure rate (P level) (reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
-
G
5
V
1
2
100 mΩ max.
5 ms max.
5 ms max.
1,000 MΩ min. (at 500 VDC between coil and contacts,
at 250 VDC between contacts of same polarity.)
1,000 VAC, 50/60 Hz for 1 min
400 VAC, 50/60 Hz for 1 min
10 to 55 to 10 Hz, 1.65 mm single amplitude
(3.3 mm double amplitude)
10 to 55 to 10 Hz, 1.65 mm single amplitude
(3.3 mm double amplitude)
1,000 m/s2
100 m/s2
5,000,000 operations min. (at 36,000 operations/hr)
100,000 operations min.
(under rated load, at 1,800 operations/hr)
1 mA at 5 VDC
-40°C to 70°C (Standard), -40°C to 90°C (G5V-1-T90)
(with no icing or condensation)
5% to 85%
Approx. 2 g
Note: The values here are initial values.
*1. Measured with 10 mA at 1 VDC with a voltage drop
method.
*2. Measured with a 500 VDC megohmmeter between
coil and contacts and a 250 VDC megohmmeter
between contacts with the same polarity applied to
the same parts as those used for checking the
dielectric strength.
*3. This value was measured at a switching frequency
of 120 operations/min and the criterion of contact
resistance is 100 Ω.
This value may vary depending on the switching
frequency and operating environment. Always
double-check relay suitability under actual operating
conditions.
G5V-1
Low Signal Relay
■Engineering Data
●Durability
Durability (x104 operations)
Switching current (A)
5
3
1
0.7
0.5
●Ambient Temperature vs.
Maximum Coil Voltage
500
Maximum coil voltage (%)
●Maximum Switching Capacity
300
24 VDC resistive load
100
70
250
200
G5V-1-T90
150
50
100
30
Standard
0.3
10
DC resistive load
0.1
10
30
AC resistive
load
50 70 100
7
5
0
300 500
50
125 VAC
resistive load
0.2
0.4
0.6
0.8
1.0
1.2
0
−40
−20
0
20
40
60 70 80 90 100
Ambient temperature (°C)
Switching current (A)
Switching voltage (V)
Note: The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
Sample: G5V-1
Number of Relays: 10 pcs
G5V-1-T90
On the basis of rated voltage (%)
100
●Shock Malfunction
max.
X
80
min.
60
40
max.
X
100
Y
Sample: G5V-1-T90
Number of Relays: 10 pcs
−
X
-20
0
20
40
60
max.
−
X
min.
Must operate voltage
Must release voltage
0
−60
80 100
Z
1,000
400
200
200
40
20
-40
600
X
1,000
min.
60
Must operate voltage
Must release voltage
0
-60
800
max.
80
min.
20
G
5
V
1
1,000
-
On the basis of rated voltage (%)
●Ambient Temperature vs. Must
Operate or Must Release Voltage
G5V-1
−40
−20
0
20
Ambient temperature (°C)
40
60
Shock direction
X
X'
Y
80 100
Ambient temperature (°C)
400 Deenergized
600
1,000
Z'
Y'
Z
Z'
1,000
X'
800
1,000
Y'
Energized
Unit: m/s2
Sample: G5V-1 12 VDC
Number of Relays: 10 pcs
Test conditions: Shock is applied in ±X, ±Y, and
±Z directions three times each with and without
energizing the Relays to check the number of
contact malfunctions.
●Dial Pulse Test *1
●Contact Reliability Test *1, *2
On the basis of rated voltage (%)
Contact resistance (mΩ)
1,000
80
70 Must operate voltage
max.
60
50
min.
max.
Must release voltage
40
30
min.
20
Contact resistance (mΩ)
Sample: G5V-1 12 VDC
10 Number of Relays: 6 pcs
1,000 Test conditions: Contact load
WJ-139 (with arc-killer)
500
Switching frequency: 20PPS
300
NO
contact
50
Contact resistance
30
100
10
0
50 100
NC contact
200
max.
max.
50
40
30
min.
min.
20
max.
min.
min.
5,000 10,000 50,000
10
0
5
10
50 100
500 1,000
Operating frequency (×104 operations)
3
Rotation (×10 turns)
*1.
*2.
NO contact
100
max.
NC
contact
500 1,000
Sample: G5V-1 12 VDC
Number of Relays: 10 pcs
500 Test conditions: Resistive
load at 5 VDC 1 mA
400
Switching frequency:
300 7,200 operations/h
The tests were conducted at an ambient temperature of 23°C.
The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary
according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use.
●High-frequency Characteristics
• Test Conditions
G5V-1
HR 8502A
Network
analyzer
RF
R
HP A
8501A
Storage
normalizer B
HR 8502A
Transmission
reflection
test-set
Terminator
50Ω
Terminals which were not being measured were terminated with 50 Ω.
Measuring impedance: 50 Ω
Note: The high-frequency characteristics data were measured using a dedicated circuit board and
actual values will vary depending on the usage conditions. Check the characteristics of the actual
equipment being used.
3
G5V-1
Low Signal Relay
●High-frequency Characteristics
(Insertion Loss) *1, *2
20
0
Return loss (dB)
Sample: G5V-1
Number of Relays: 5 pcs
(Average value (initial))
(Average value (initial))
Insertion loss (dB)
Isolation (dB)
(Average value (initial))
0
●High-frequency Characteristics
(Return Loss, V.SWR) *1, *2
0.5
40
Between a-c
0
1.4
Sample: G5V-1
Number of Relays: 5 pcs
10
1.3
20
1.2
1.0
Return loss
60
1.1
30
Between b-c
1.5
80
1.0
40
V.SWR
Sample: G5V-1
Number of Relays: 5 pcs
Frequency (MHz)
2.0
100
1
3
5
10
30
50
1
100
3
5
10
30
Must operate time
Must release time
25
3
5
10
30
50
100
Frequency (MHz)
●Distribution of Bounce Time *1
Number of contacts
Number of contacts
Sample: G5V-1 12 VDC
Number of Relays: 50 pcs
1
20
30
Sample:
G5V-1 12 VDC
Number of Relays:
25 50 pcs
Operating bounce time
Release bounce time
20
15
15
10
10
-
G
5
V
1
30
50
100
Frequency (MHz)
Frequency (MHz)
●Must Operate and Must Release
Time Distribution *1
50
*1.
*2.
5
0
5
0.5
1
1.5
2
2.5
3
3.5
4
0
1
2
3
4
5
Time (ms)
6
7
8
The tests were conducted at an ambient
temperature of 23°C.
High-frequency characteristics depend on
the PCB to which the Relay is mounted.
Always check these characteristics,
including endurance, in the actual machine
before use.
Time (ms)
■Dimensions
PCB Mounting Holes
(Bottom View)
G5V-1
7.5 max.
(7.3)*
12.5 max.
(12.3)*
2.54
6-1 dia. holes
Terminal Arrangement/
Internal Connections
(Bottom View)
(1.11)
2.54
10 max.
(9.9)* 0.5
5.08±0.1
3.5
1
2
5
10
9
6
(1.11)
0.5
0.3
2.54
(1.07)
0.5
0.3
* Average value
(No coil polarity)
7.62
(1.07)
10.16±0.1
Note:
indicate the product's directional marks.
Note: Each value has a tolerance of ±0.3 mm.
■Approved Standards
■Precautions
UL recognized:
(File No. E41515)
CSA certified: (File No. LR31928)
Model
Contact
Coil ratings
form
G5V-1
SPDT
(1c)
3 to 24 VDC
G5V-1-T90
SPDT
(1c)
5 to 24 VDC
4
Contact ratings
1 A, 30 VDC at 40°C
0.3 A, 110 VDC at 40°C
0.5 A, 125 VAC at 40°C
1 A, 30 VDC at 90°C
0.5 A, 125 VAC at 90°C
• Please refer to “PCB Relays Common Precautions” for correct
use.
Number of test
operations
6,000
100,000
100,000
100,000
Correct Use
• Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON
continuously for long periods (without switching) can lead to
unstable contacts, because the heat generated by the coil itself
will affect the insulation, causing a film to develop on the contact
surfaces. Be sure to use a fail-safe circuit design that provides
protection against contact failure or coil burnout.
• Relay Handling
When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent, and keep
the solvent temperature to less than 40°C. Do not put the Relay
in a cold cleaning bath immediately after soldering.
V.SWR
●High-frequency Characteristics
(Isolation) *1, *2
G5V-1
Low Signal Relay
-
G
5
V
1
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K048-E1-07
1216(0207)(O)